CNVTYPE¶
CNVTYPE type {0}
This keyword specifies the method of incident-particle spectrum conversion using the GRPCONVERT keyword. The default 0 value uses an equal-lethargy per bin approximation to convert flux values over bin boundaries while using 1 causes the conversion to use an equal-energy approximation. Example usage: